Applications
Lisinopril Ph. Eur. System Suitability Reference Solution B on Kinetex 5 µm XB-C18 250 x 4.6 mm on Agilent 1100 LC/UV
26302
Separation Mode: Reversed Phase
Reversed Phase
Ph.Eur. M.1120
XB-C18
HPLC
Antihypertensive Agents
Pharmaceutical/Biopharmaceutical
Pharmaceutical
Therapeutic / Clinical

Applications

Lisinopril Ph. Eur. System Suitability Reference Solution B on Kinetex 5 µm XB-C18 250 x 4.6 mm on Agilent 1100 LC/UV

Analytes

1

Analyte not found

Conditions

LC Conditions (App ID: 26302)
Official Method:Ph.Eur. M.1120
Column:Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Brand Name:Kinetex
Part No:00G-4605-E0
Elution Type:Gradient
Mobile Phase:A: Mix 3 volumes of acetonitrile R1 and 97 volumes of 3.12 g/L solution of sodium dihydrogen phosphate R previously adjusted to pH 3.8 with dilute phosphoric acid R
B: Mix 20.5 volumes of acetonitrile R1 and 79.5 volumes of 3.12 g/L solution of phosphoric acid R
Gradient Profile:
Step No.Time(min)%A%B
10100
22100
3370100
4620100
562.5100
666100
Flow Rate:1.6 mL/min
Temperature:50°C
System:Agilent Technologies Agilent Technologies
Detection:LC/UV (DAD, PDA) nm (nanometers) @ 0°C

Order Items Used in This Application

Similar Applications
Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm XB-C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea