Product Information
Phase Detail
CLARICEP Irregular CM Silica Columns
Claricep irregular silica flash columns provide significant performance over traditional irregular flash columns on the market
CLARICEP Irregular CM Silica Columns

  • Significantly improved performance over regular flash columns
  • Silica deactivated by proprietary process
  • Alternative selectivity for complex purification requirements

claricep_irrgular_cm_silica


Better Peak Shape with CM Silica

HPLC Test

Unmodified and deactivated silica were packed into individual stainless steel columns (4.6 x 150 mm) and then evaluated on a HPLC system.

HPLC Condition:

Dimension:
4.6 x 150 mm
Mobile Phase:
Dichloromethane/Methanol (98:2)
Flow Rate:
1.8 mL/min
Injection Volume:
5 µL
Temperature:
30 °C
Detector:
UV @ 254 nm
Sample:
Catechol 100 µg/mL

CLARICEP Irregular CM Silica Screw-on Columns
The Screw-on series of Flash columns are a new feature that allows the user to load a solid phase, viscous phase, or simply open the cap for a more user friendly analysis.

Which Screw-on Series should I order ?

CLARICEP i-Series

The i-Series features a managed column head space with a secured screw-on lid. This new design allows either loading of liquid samples directly onto the column head or loading of impregnated solid sample directly into the space. Users will benefit from:

  • Choice of loading method based on sample properties
  • Narrow band for liquid samples because of wide loading area
  • Dry-loading of solid impregnated samples minimizes band broadening
  • Customized loading method upon user preference

Ordering Information
Part Number starts with “SN”. As an example, to order CM140012-0 in i-series, Part Number to order is SN-CM140012-0


CLARICEP c-Series

The c-Series shares the same design, but the column outlet does not have a luer lock structure, this simplifies tubing connection across various flash systems.

Compatible with instruments from the following:
  • Agela Technologies
  • Buchi
  • Grace
  • Interchim
  • Other brands

Ordering Information
Part Number starts with “C”. As an example, to order CM140012-0 in c-series, Part Number to order is C-CM140012-0

CLARICEP s-Series

The s-Series columns are fully packed without a head void. In addition, the Luer lock fittings for both inlet and outlet allows easy operation of tandem columns or the coupling of a loading cartridge.

Compatible with instruments from the following:
  • Biotage

Ordering Information
Part Number starts with “S”. As an example, to order CM140012-0 in s-series, Part Number to order is S-CM140012-0