Product Information
Industry
Environmental
Environmental
From Sample Preparation to Analysis, We Have You Covered

We understand the challenges faced by environmental laboratories - beginning with the challenge of variable sample matrix, through demanding chromatographic separation requirements and final analysis.  Let us help improve the robustness of your workflow and boost your productivity with our portfolio of sample preparation, GC, and LC products designed to meet your expectations.

  • Tackle challenging environmental matrices with our portfolio of sample preparation products
  • Achieve the chromatographic performance you need with our extensive portfolio of GC and LC products and wide selection of phases
  • Consult with our separation experts for help with phase selection, method optimization, and workflow improvement suggestions


Technical Notes

EPA Method 537.1: PFAS in Drinking Water Using Strata SDB-L Solid Phase Extraction (SPE) and a Luna Omega 1.6 μm PS C18 UHPLC Column
Per-and Polyfluoroalkyl Substances (PFAS) Extraction by LC-MS/MS Using Strata® PFAS for a Stacked Solid Phase Extraction (SPE) Solution
Environmental Sample Prep guide
Top Tips!

Check out our most commonly asked environmental testing questions.

How may I improve the recovery of organic volatiles during a GC headspace analysis of drinking water?

Headspace sampling from drinking water is typically performed by first equilibrating the vial at a temperature of 80 °C, as a higher temperature would generate excessive pressure within the vial with respect to the atmospheric boiling point of water.  The first consideration is the duration of the equilibration to assure that analytes volatilize consistently, and these equilibration times are often around 30 – 45 min.  Be mindful that low-boiling polar analytes, such as methanol, will still exhibit hydrogen-bonding with water, and will need that long equilibration to assure of volatilization.  You may also add a kosmotropic salt, such as magnesium sulfate (MgSO4) to disrupt the ability of water to solvate your targeted volatile organic analytes, facilitating the volatility of these anlaytes.

Why do my retention times for PFAS analytes begin to shift earlier after many consecutive injections during an HPLC sequence?

PFAS compounds have properties that can both streamline and complicate an LC analysis.  On the one hand, a PFAS with a carboxylate or sulfonate head will essentially always be deprotonated when working within typical LC reversed phase conditions.  The electron-withdrawing capacity of the fluorines along the hydrophobic tail will significantly lower the pKa of a carboxylatis acid head to the point of essentially acting as a strong acid.  The challenge is that the structure of a PFAS is comparable to an ion-pair reagent, consisting of an anionic head and a long perfluorinated carbon tail that is exceedingly hydrophobic.  Consecutive injections of PFAS samples on a C18 column run the risk of residual amounts of analyte remaining in the stationary phase, such that the hydrophobic tail of the PFAS is burrowed into the hydrophobic C18 phase, while the ionic head faces the mobile phase.  The accumulation of charge (negative in this instance) within the mobile phase will lower the hydrophobicity of the C18 phase, particularly as the anionic heads of PFAS compounds repel one another.  This may be addressed by implementing a routing cleaning method using pure solvents intermittently during a prolonged sample sequence.

Visit Our Guru

We’re traveling the globe to meet our customers, come visit us!  

ACIL 2021 Policy and Practice Meeting Washington, DC
NEMC 2021 August 2 - 5, 2021
ACIL 2021 October 12 - 15, 2021
Featured Products

Zebron™ ZB-PAH-EU and ZB-PAH-CT GC Columns Guide

  • Up to 70 % Faster PAH Analysis
  • Elevated Temperature Stability (340/360°C)
  • Great Resolution of Critical Isomers, e.g. Benzo[b,j,k] fluoranthene
  • Enhanced Resolution for Chrysene and Triphenylene (PAH Interferences)
  • Increased Benzo[b,k] fluoranthene Separation
  • Optimal Performance and Resolution of Regulated PAH Isomers

Strata PFAS (WAX/GCB) for complex matrices – Soils, Wastewaters

  • Combines carbon cleanup and WAX in one column format
  • Reduce the need for multiple tubes, transfer steps, and wasted time
  • Recommended Applications: DOD QSM 5.1/5.3

NEW! Luna Omega C18 LC Columns. Now Available in 3 µm and 5 µm

Thermally modified pore structures result in greater separation power, better peak shape, and extreme ruggedness and dependability.